  • Code: 03-006
  • Display: S: Motor error T: Error: #03-006 Turn off then on
  • Description: After Black OPC BLDC motor is operated, the ready signal is not occurred within 2.5 sec
  • Remedy: 1. Check the 24V power. 2. If 24V power is not occurred, replace the SMPS. 3. Check the motor connector and Main-PBA connector. 4. Replace the BLDC motor. 5. Replace the Main-PBA.
  • Code: 03-007
  • Display: S: Motor error T: Error: #03-007 Turn off then on
  • Description: After Dev BLDC motor is operated, the ready signal is not occured within 2.5 sec.
  • Remedy: 1. Check the 24V power. 2. If 24V power is not occurred, replace the SMPS. 3. Check the motor connector and Main-PBA connector. 4. Replace the BLDC motor. 5. Replace the Main-PBA.
  • Code: 03-008
  • Display: S: Motor error T: Error: #03-008 Turn off then on
  • Description: After Fuser OPC BLDC motor is operated, the ready signal is not occurred within 1 sec.
  • Remedy: 1. Check the 24V power. 2. If 24V power is not occurred, replace the SMPS. 3. Check the motor connector and Main-PBA connector. 4. Replace the BLDC motor. 5. Replace the Main-PBA.
  • Code: 03-015
  • Display: S: Fan error T: Error: #03-015 Turn off then on
  • Description: Fan does not operate.
  • Remedy: 1. Check the CN7 connector on Main-PBA. 2. If the Fan operates and the error message is displayed, replace the Main-PBA.
  • Code: 04
  • Display: Paper Jam in tray2
  • Description: Paper has jammed in the feeding area of the tray.
  • Remedy: 1. Take out the 2nd cassette and remove the jammed paper. 2. If the pick up roller does not rotate, check the Gear Pick up(JC97-02895A). If it is defective, replace it. 3. If the pick up roller rotates but the paper is not feeding, replace the Clutch-Feed(JC47-00023A). 4. Reconnect the CN9 connector on Main PBA 5. Check the sensor and connector in SCF.
  • Code: 04-001, 04-004
  • Display: S: LSU error T: Error: #04-001,4,7,10 Turn off then on
  • Description: After LD on, the Laser beam detect signal is not occurred or irregular.
  • Remedy: 1. Replace the Main board. 2. If the problem persists after replacing the Main board, replace the LSU unit.