- Code: 0125
- Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
- Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
- Remedy: Check Heater Check Thermostat Check Thermistor
- Code: 0126
- Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
- Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
- Remedy: Check Heater Check Thermostat Check Thermistor
- Code: 0130
- Description: There is a problem with Thermistor for Print Heater.
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Remedy: Check Cable connection around Thermistor Thermistor replacement
- Code: 0135
- Description: Heater is unusually hot. Print Heater temperature has reached 60°C and above.
- Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
- Remedy: Check Heater Check Thermostat Check Thermistor
- Code: 0140
- Description: There is a problem with Thermistor for dryer (2 lines/upper).
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Remedy: Check Cable connection around Thermistor Thermistor replacement
- Code: 0141
- Description: There is a problem with Thermistor for dryer (2 lines/middle).
- Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
- Remedy: Check Cable connection around Thermistor Thermistor replacement