  • Code: 0125
  • Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
  • Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
  • Remedy: Check Heater Check Thermostat Check Thermistor
  • Code: 0126
  • Description: Heater is unusually hot. Pre-Heater F temperature has reached 60°C and above.
  • Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
  • Remedy: Check Heater Check Thermostat Check Thermistor
  • Code: 0130
  • Description: There is a problem with Thermistor for Print Heater.
  • Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
  • Remedy: Check Cable connection around Thermistor Thermistor replacement
  • Code: 0135
  • Description: Heater is unusually hot. Print Heater temperature has reached 60°C and above.
  • Causes: Heater Cable connection has a problem. Thermostat has a problem (not working). Thermistor has a problem.
  • Remedy: Check Heater Check Thermostat Check Thermistor
  • Code: 0140
  • Description: There is a problem with Thermistor for dryer (2 lines/upper).
  • Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
  • Remedy: Check Cable connection around Thermistor Thermistor replacement
  • Code: 0141
  • Description: There is a problem with Thermistor for dryer (2 lines/middle).
  • Causes: Device has a problem. Thermistor Cable has short circuited or cutline.
  • Remedy: Check Cable connection around Thermistor Thermistor replacement