Catalog
Sign In
Contacts
Forum
Eng
Ricoh SPC430DN
Error Codes List page 22
Error Code:
All codes
195
202
203
204
220
222
230
231
232
233
234
235
236
237
240
241
285
290
291
292
293
312
313
314
315
325
360
361
362
363
364
365
366
367
372
373
374
375
380
381
396
397
400
442
443
452
460
466
491
492
495
498
501
502
503
504
520
521
522
530
531
532
533
534
535
536
537
540
541
542
543
544
545
547
551
552
553
554
555
557
559
561
563
564
565
622
623
624
641
652
653
669
670
671
681
682
683
687
690
816
819
820
833
853
854
855, 856
857
858
859
860
861
863
864
865
866
867
868
870
872
873
874
875
876
877
878
881
899
900
920
921
990
991
992
995
997
998
page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Code: 899
Description: Software error A software error occurred in the GW controller.
Causes: • Cycle the machine off/on • Update controller firmware • Controller board defective
Remedy:
Code: 900
Description: Electric counter error Abnormal data in the counters.
Causes: • Defective NVRAM • Defective controller
Remedy: 1. Check the connection between the NVRAM and controller. 2. Replace the NVRAM. 3. Replace the controller.
Code: 920
Description: Printer application error An error is detected in the printer application program.
Causes: • Defective software • Unexpected hardware resource (e.g., memory shortage)
Remedy: 1. Software defective; switch off/on, or change the controller firmware if the problem is not solved 2. Insufficient memory
Code: 921
Description: Printer font error A necessary font is not found in the SD card.
Causes: • A necessary font is not found in the SD card. • The SD card data is corrupted.
Remedy: Check that the SD card has the correct data.
Code: 990
Description: Software performance error The software makes an unexpected operation.
Causes: • Defective software • Defective controller • Software error
Remedy: 1. Turn the main switch off and on. 2. Reinstall the controller and/or engine main firmware.
Code: 991
Description: Software continuity error The software has attempted to perform an unexpected operation. However, unlike SC 990, the object of the error is continuity of the software.
Causes: • Software program error • Internal parameter incorrect, insufficient working memory.
Remedy: This SC is not displayed on the operation panel (logging only).