PrintCopy.info service

Ricoh SPC430DN

Error Codes List page 13

  • Code: 545
  • Description: Heating roller fusing lamp consecutive full power 1
    When the fusing unit is not running in the ready condition, the heating roller fusing lamp keeps on full power for 30 seconds.
  • Causes: • Broken heating roller thermostat • Broken heating roller fusing lamp
  • Remedy: 1. Replace the heating roller thermostat. 2. Replace the heating roller fusing lamp.
  • Code: 547
  • Description: Zero cross error
    • The zero cross signal is detected for 0.05 seconds three times even though the heater relay is off when turning on the main power. • The zero cross signal is not detected for 3 seconds even though the heater relay is on after turning on the main power or closing the front door. • The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected zero cross signal is less than 45.
  • Causes: • Defective fusing lamp relay • Defective fusing lamp relay circuit • Unstable power supply
  • Remedy: 1. Check the power supply source. 2. Replace the shorted 24V fuse on the PSU. 3. Replace the PSU
  • Code: 551
  • Description: Heating roller thermistor (end) error 2
    The temperature measured by the heating roller thermistor (end) does not reach 0° C for 6 seconds.
  • Causes: • Loose connection of heating roller thermistor (end) • Defective heating roller thermistor (end)
  • Remedy: 1. Check that the heating roller thermistor (end) is firmly connected. 2. Replace the heating roller thermistor (end).
  • Code: 552
  • Description: Heating roller warm-up error 2
    The heating roller temperature does not reach the ready temperature while 70 seconds after the heating lamp on.
  • Causes: • Dirty or defective thermistor (end) • Heating roller fusing lamp broken • Defected thermostat • Defective heating roller fusing lampamp on.
  • Remedy: 1. Check if the heating roller thermistor (end) is firmly connected. 2. Replace the heating roller thermistor (end). 3. Replace the heating roller fusing lamp.
  • Code: 553
  • Description: Heating roller fusing lamp overheat 2 (software error)
    The detected pressure roller temperature stays at 230°C or more for 1 second.
  • Causes: • Defective PSU • Defective BCU
  • Remedy: 1. Replace the heating roller thermistor (end). 2. Replace the PSU. 3. Replace the BCU.
  • Code: 554
  • Description: Heating roller fusing lamp overheat 2 (hardware error)
    The heating roller thermistor (end) detects 250°C or more.
  • Causes: • Defective heating roller thermistor (end) • Defective PSU • Defective BCU • Defective fusing control system
  • Remedy: 1. Replace the heating roller thermistor (end). 2. Replace the PSU. 3. Replace the BCU.