Description: Software write parameter setting error
An unstable area at the storage destination in the settings table is set NULL for the parameter received by the write module.
Causes: • Software defective
Code: 990
Description: Software error 1
The software performs an unexpected function and the program cannot continue.
Causes: • Software defective, re-boot
Code: 991
Description: Software error 2
The software performs an unexpected function. However, unlike SC990, recovery processing allows the program to continue.
Causes: • Software defective, re-boot
Code: 992
Description: Software error 3: Undefined
An error not controlled by the system occurred (the error does not come under any other SC code).
Causes: • Software defective • Turn the machine power off and on. The machine cannot be used until this error is corrected.
Code: 995
Description: Machine Type Information Error
After the machine is powered on, a mismatch is detected between the CPM information sent from the controller to the engine.
Causes: • Replace the controller board with the correct board.
Code: 997
Description: Software Error 4: Cannot select application function
An application does not start after the user pushed the correct key on the operation panel.
Causes: • Software bug • A RAM or DIMM option necessary for the application is not installed or not installed correctly.