Description: High voltage output error: Charge unit /Development unit This SC is issued if the engine board detects a short in the power pack 10 times consecutively.
Causes: Open circuit (+) / Short circuit (-)
Remedy: • Turn the main power off/on. • Replace the board. • Check the connector connection.
Code: SC332-00
Description: Toner supply transfer lock This SC is issued if the error that the toner is not supplied is detected n times consecutively (n: SP2-931-005) on the condition that the toner cartridge is not in end
Causes: • Overload on the toner transferring part (clogging of toner) • Screw for detecting PCDU does not turn • Detector element (sensor) defective: light leak • Supplying pick does not engage • Defective Supplying clutch • Defective Drive mechanism of screw for supplying toner cartridge
Remedy: • Turn the main power off/on.
Code: SC364-00
Description: Toner End Sensor output count error When the average value of the toner end sensor output count is 0 n times consecutively (n: SP2-931-003)
Causes: • Connector contact failure/disconnected/broken • Detector element (sensor) does not emit light • Detecting surface inside the developing device is stained
Remedy: • Turn the main power off/on.
Code: SC440-00
Description: High voltage output error: Transfer unit This SC is issued if the engine board detects a short in the power pack 10 times consecutively.
Causes: Open circuit (+) / Short circuit (-)
Remedy: • Turn the main power off/on. • Replace the board • Check the connector connection.
Code: SC460-00
Description: High voltage output error: Paper separation This SC is issued if the engine board detects a short 10 times consecutively during PWM signal output of the paper separation.
Causes: Short Circuit
Remedy: • Turn the main power off/on. • Replace the board. • Check the connector connection.
Code: SC498-00
Description: Temp Humid Sensor error • Temperature Sensor output error: Out of range between 076 V and 2.90 V • Humidity Sensor output error: 2.4 V or more