PrintCopy.info service

Ricoh SP6430DN

Error Codes List page 2

  • Code: SC302-00
  • Description: High voltage output error: Charge unit /Development unit This SC is issued if the engine board detects a short in the power pack 10 times consecutively.
  • Causes: Open circuit (+) / Short circuit (-)
  • Remedy: • Turn the main power off/on. • Replace the board. • Check the connector connection.
  • Code: SC332-00
  • Description: Toner supply transfer lock This SC is issued if the error that the toner is not supplied is detected n times consecutively (n: SP2-931-005) on the condition that the toner cartridge is not in end
  • Causes: • Overload on the toner transferring part (clogging of toner) • Screw for detecting PCDU does not turn • Detector element (sensor) defective: light leak • Supplying pick does not engage • Defective Supplying clutch • Defective Drive mechanism of screw for supplying toner cartridge
  • Remedy: • Turn the main power off/on.
  • Code: SC364-00
  • Description: Toner End Sensor output count error When the average value of the toner end sensor output count is 0 n times consecutively (n: SP2-931-003)
  • Causes: • Connector contact failure/disconnected/broken • Detector element (sensor) does not emit light • Detecting surface inside the developing device is stained
  • Remedy: • Turn the main power off/on.
  • Code: SC440-00
  • Description: High voltage output error: Transfer unit This SC is issued if the engine board detects a short in the power pack 10 times consecutively.
  • Causes: Open circuit (+) / Short circuit (-)
  • Remedy: • Turn the main power off/on. • Replace the board • Check the connector connection.
  • Code: SC460-00
  • Description: High voltage output error: Paper separation This SC is issued if the engine board detects a short 10 times consecutively during PWM signal output of the paper separation.
  • Causes: Short Circuit
  • Remedy: • Turn the main power off/on. • Replace the board. • Check the connector connection.
  • Code: SC498-00
  • Description: Temp Humid Sensor error • Temperature Sensor output error: Out of range between 076 V and 2.90 V • Humidity Sensor output error: 2.4 V or more
  • Causes: • Unmounted Sensor (Unset connector or broken wire) • Failed Sensor
  • Remedy: • Check that the connector is set. • Replace the Sensor.