PrintCopy.info service

Ricoh MPCW2200SP

Error Codes List page 2

  • Code: SC161-1
  • Description: IPU Error 1: Volans Configuration Error At power on, or when the machine returned from energy save mode, FPGA (flash program) did not configure correctly within 500 ms, or an FPGA communication check failed.
  • Causes: •X Check all harness connections to the IPU for a loose, broken, defective connection •X IPU defective
  • Remedy:
  • Code: SC165
  • Description: Illegal Copy Prevention Function Error The illegal copy prevention function failed to initialize at power on, or when the machine returned from the energy save mode, because the ICIB3 board was not detected or was not installed correctly. Note: The ICIB3 (option) is the PCB installed on the back of the machine that controls the function that prohibits illegal copying of currency, bank notes, etc.
  • Causes: •X Check installation and connection of the ICIB3 board •X ICIB3 defective
  • Remedy:
  • Code: SC200
  • Description: Suction Cap HP Sensor Error The maintenance unit slide sensor did not detect the suction cap and wiper blade assembly at home position.
  • Causes: •X HP sensor connection loose, broken, defective •X Paper or other obstacle blocking movement of the mechanism •X HP sensor defective
  • Remedy:
  • Code: SC201-01
  • Description: Print Head Caps Home Position Sensor Error The cap sensor in he maintenance unit failed to detect the left cradle at the up position or down position (home position).
  • Causes: •X HP sensor connection loose, broken, defective •X Paper or other obstacle blocking movement of the mechanism •X HP sensor defective
  • Remedy:
  • Code: SC201-02
  • Description: Cleaner Unit Slider Sensor Error The slider sensor at the back of the maintenance unit failed to detect the cleaner unit at the forward position or the rear position (home position. The left cradle, suction cap, rubber wiper blade, and wipers comprise the maintenance cleaning unit.
  • Causes: •X HP sensor connection loose, broken, defective •X Paper or other obstacle blocking operation of the motor •X HP sensor defective •X Motor defective
  • Remedy:
  • Code: SC202
  • Description: Ink Level Detection Feeler Position Error One of the following conditions existed: •X When air was purged one or more of the feelers could not be detected so the operation could not continue. •X When the maintenance pump attempted to apply negative pressure on the print head ink tank, the feeler could not be detected at its prescribed position after the pressure was applied. •X OCFS could not detect the feeler(s) after the feeler sensor performed the check after filling.
  • Causes: •X Feeler cannot be detected because it is out of position (loose, broken, defective, or blocked by an obstruction) •X Air release solenoid blocked •X Maintenance unit defective •X Print head ink tank defective •X Air release solenoid defective
  • Remedy: