  • Code: SC221
  • Description: Laser Synchronization Detector Error: K Leading Edge (Not LD0)
    While the polygon motor is rotating normally, no synchronizing detection signal is output for black, leading edge for any LD other than LD0.
  • Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
  • Code: SC222
  • Description: Laser Synchronization Detector Error: Y Leading Edge: LD0
    While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 yellow, leading edge.
  • Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
  • Code: SC223
  • Description: Laser Synchronization Detector Error: Y Leading Edge (Not LD0)
    While the polygon motor is rotating normally, no synchronizing detection signal is output for yellow, leading edge for any LD other than LD0.
  • Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
  • Code: SC224
  • Description: Laser Synchronization Detector Error: M Leading Edge: LD0
    While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 magenta, leading edge.
  • Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
  • Code: SC225
  • Description: Laser Synchronization Detector Error: M Leading Edge (Not LD0)
    While the polygon motor is rotating normally, no synchronizing detection signal is output for magenta, leading edge for any LD other than LD0.
  • Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective
  • Code: SC226
  • Description: Laser Synchronization Detector Error: C Leading Edge: LD0
    While the polygon motor is rotating normally, no synchronizing detection signal is output for LD0 cyan, leading edge.
  • Causes: • Harness between the laser synchronizing detector and I/F unit is disconnected, defective • Check all connections between LD unit, LDB, IPU • LD unit • LDB defective • IPU defective