Description: Thermal Head Energy Pulse error: The CPU detects an abnormal ID signal from the thermal head energy control pulse.
Causes: Thermal head connector Thermal head MPU
Code: E-12
Description: Pressure Plate error: The pressure plate home position sensor does not turn on within 6 seconds during initialization. Both the pressure plate home position and pressure plate limit sensors turn on when the main SW is turned on. The pressure plate home position sensor does not turn off when the pressure plate limit sensor does not turn on within 4.5 seconds when compressing the ejected master.
Causes: Pressure plate drive Pressure plate motor Plate position sensors Master eject error
Code: E-13
Description: Scanner error: The scanner HP sensor does not turn on within 14.0 seconds after the main switch turns on. On the Initial Movement, the Scanner HP sensor does not turn off when the scanner moves 20.0 mm towards the scanning position. On the Initial Movement, the Scanner HP sensor does not turn on within 2.0 seconds after the main switch turns on.
Causes: Scanner drive Scanner HP sensor Scanner motor
Code: E-14
Description: SBU error: The MPU board cannot communicate with SBU or communication data is not expected. The value of the SBU white level adjustment is out of the correct range. The value of the SBU black level adjustment is out of the correct range. The power of LED lamp is not enough.