Description: White level detection error • The white level cannot be adjusted to the second target level within the target during auto gain control.
Causes: • SBU defective • LED defective • IDB (LED driver) defective • IPU defective • Power/signal harness defective • Scanner drive error • Condensation in scanner unit • Mirrors or lenses dirty or positioned incorrectly • White plate dirty or installed incorrectly
Remedy: • Cycle the machine off/on. • Reconnect the power/signal harness. • Reattach/clean the mirrors/lenses. • Reattach/clean the white plate. • Replace the SBU board. • Replace the LED board. • Replace the IDB board. • Replace the IPU board. • Replace the SIO board. • Replace the power/signal harness.
Code: SC144-00
Description: SBU Communication Error • Connection to SBU cannot be confirmed. (Connection detection error) • Cannot communicate with the SBU, or the communication result is abnormal.
Causes: • SBU defective • The other side of the communication (BCU, IPU etc.) defective • Power/signal harness defective
Remedy: • Cycle the machine off/on. • Reconnect the power/signal harness. • Replace the SBU board. • Replace the IPU board. • Replace the BCU board. • Replace the power/signal harness.
Code: SC161-01
Description: IPU Error (LSYNC abnormal) An error occurred during the self-diagnostic test performed every time the machine is turned on, or returns to full operation from energy save mode.
Description: Copy data security unit error • The copy data security option is enabled in the User Tools but the option board is detected as missing or defective. • The copy data security option was detected as defective when the machine was turned on or returned from energy save mode.
Causes: • Copy data security unit board not installed correctly • Copy data security unit board defective
Remedy: • Reinstall the copy data security unit board. • Replace the copy data security unit board.
Code: SC185-00
Description: CIS transmission error The data read from the ASIC register on the CIS were not as expected. Details: • Occurs when a serial communication error between the CIS board and the DF board is detected. Occurs also when an error is detected during initialization of the ASIC on the CIS. • This can happen during initialization and feeding. The first and second consecutive occurrences of each constitute jams. The third occurrence constitutes an SC.
Causes: • Connector or harness between DF board and CIS board is disconnected or defective • ASIC on the CIS is defective • Boot failure of ASIC on the CIS
Remedy: • Reconnect the power/signal harness. • Replace the CIS and CIPB. • Replace the ADF main control board. • Replace the power/signal harness.