Catalog
Sign In
Contacts
Forum
Eng
Ricoh A295 Aficio 1105 Bellini
Error Codes List page 2
Error Code:
All codes
SC101
SC120
SC121
SC124
SC125
SC126
SC127
SC128
SC129
SC130
SC300
SC301
SC302
SC303
SC305
SC306
SC310
SC311
SC312
SC314
SC321
SC322
SC323
SC326
SC327
SC328
SC329
SC330
SC331
SC332
SC335
SC336
SC337
SC338
SC340
SC341
SC342
SC345
SC350
SC351
SC352
SC353
SC354
SC360
SC362
SC364
SC366
SC367
SC370
SC372
SC374
SC376
SC380
SC382
SC384
SC386
SC390
SC391
SC400
SC401
SC430
SC440
SC441
SC493
SC494
SC495
SC496
SC497
SC501
SC502
SC503
SC505
SC510
SC511
SC515
SC516
SC520
SC521
SC530
SC531
SC541
SC542
SC543
SC544
SC545
SC546
SC547
SC590
SC601
SC602
SC620
SC621
SC622
SC625
SC626
SC630
SC635
SC636
SC700
SC701
SC702
SC703
SC704
SC705
SC720
SC722
SC724
SC725
SC726
SC727
SC729
SC730
SC731
SC735
SC736
SC737
SC738
SC740
SC741
SC900
SC901
SC951
SC953
SC954
SC955
SC956
SC957
SC958
SC959
SC960
SC961
SC962
SC963
SC964
SC966
SC970
SC980
SC982
SC984
SC990
page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
Code: SC127
Description: Scanner motor encoder rotating direction error
The scanner moves in the opposite direction from the instructed direction when initializing.
Causes: • Scanner motor defective • MCU defective
Code: SC128
Description: Scanner motor start error
The scanner motor speed does not reach the target speed until starting to read the original.
Causes: • Scanner motor defective • MCU defective • PSU defective • Too much load on scanner drive
Code: SC129
Description: Scanner motor speed control error
The scanner speed is out of standard during scanning.
Causes: • Scanner motor defective • PSU defective • MCU defective • Scanner drive defective
Code: SC130
Description: SBU error
When the main switch is turned on, the BICU cannot receive the correct signal from the SBU.
Causes: • SBU defective • BICU defective • Cable between SBU and BICU defective
Code: SC300
Description: Charge corona output error 1
The feedback voltage from the charge corona unit is too high.
Causes: • Charge P.P. defective • Poor charge corona unit connection
Code: SC301
Description: Charge corona output error 2
The control PWM for the charge corona unit is too high.
Causes: • Charge P.P. defective • Poor charge corona unit connection