All codes
E1-01
E1-20
E1-22
E1-31
E13
E2-01
E2-02
E2-03
E2-04
E2-10
E3-01
E3-02
E3-03
E3-10
E3-20
E4-01
E4-02
E4-10
E5-11
E5-17
E5-19
E5-40
E5-42
E5-60
E7-90
Code: E3-03
Description: Toner Density Sensor Gain
Causes: 1. Sensor connector disconnected. 2. Sensor defective. 3. SPC PCB connector disconnected. 4. SPC PCB defective.
Code: E3-10
Description: High Voltage Power Supply leak (1) - Grid Charge Voltage
Causes: 1. PS connector disconnected. 2. PS defective. 3. SPC PCB connector disconnected. 4. SPC PCB defective. 5. Corona Wire is abnormal. (Check for: contamination with foreign particles, broken, not installed in the proper position or loose tension)
Code: E3-20
Description: Main Motor Rotation
Causes: 1. Drive Mechanism defective. 2. Main Motor connector disconnected. 3. Main Motor defective. 4. SPC PCB connector disconnected. 5. SPC PCB defective. 6. PS defective.
Code: E4-01
Description: Fuser Warm-up Temperature
Causes: 1. Fuser Thermistor dirty. 2. Thermistor position incorrect. 3. Thermistor defective. 4. Thermistor connector disconnected. 5. Fuser Lamp connector disconnected. 6. Fuser Lamp defective. 7. Fuser Thermostat defective. 8. Thermal Fuse defective. 9. SPC PCB connector disconnected. 10. SPC PCB defective. 11. Fuser temperature low. (Adjust F6-31)
Code: E4-02
Description: Fuser Paper Jam
Causes: 1. Paper Jam in Fuser Unit. 2. Paper Exit Sensor disconnected. 3. Paper Exit Sensor defective. 4. SPC PCB connector disconnected. 5. SPC PCB defective.
Code: E4-10
Description: Fuser Fan Motor Rotation