- Code: 809
- Description: SU NAND ECC Error
The ECC error that restoration was impossible occurred in NAND FLASH of SU. - Remedy:
- Code: 811, 812, 813
- Description: SU Communication Error
Communication error between the Controller and the Scanner Unit is detected. - Remedy: Turn off and on the MFP.
- Code: 814
- Description: SU FW Removed
It is an error to notify that SU FW was erased by special key operation from a panel. - Remedy:
- Code: 890
- Description: SU System Memory Overflow
- Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the SU board
- Code: 899
- Description: CU Disconnect
In the situation that communication between CU and SU was able to establish, SU FW detected that CU FW had disappeared from a communications path (an USB line). - Remedy: Is the cable from the belt thermistor to the CU/PU board connected properly? Does the error occur again?
Connect the cable properly. Turn off and on the MFP. Replace the belt thermistor.
- Code: 901 ... 904
- Description: Belt temperature error
901: Short circuit
902: Open circuit
903: High temperature
904: Low temperature - Remedy: Is the cable from the belt thermistor to the CU/PU board connected properly? Does the error occur again?