PrintCopy.info service

OKI MC352

Error Codes List page 11

  • Code: 809
  • Description: SU NAND ECC Error
    The ECC error that restoration was impossible occurred in NAND FLASH of SU.
  • Remedy:
  • Code: 811, 812, 813
  • Description: SU Communication Error
    Communication error between the Controller and the Scanner Unit is detected.
  • Remedy: Turn off and on the MFP.
  • Code: 814
  • Description: SU FW Removed
    It is an error to notify that SU FW was erased by special key operation from a panel.
  • Remedy:
  • Code: 890
  • Description: SU System Memory Overflow
  • Remedy: Does the error occur again? Yes Turn off and on the MFP. Replace the SU board
  • Code: 899
  • Description: CU Disconnect
    In the situation that communication between CU and SU was able to establish, SU FW detected that CU FW had disappeared from a communications path (an USB line).
  • Remedy: Is the cable from the belt thermistor to the CU/PU board connected properly? Does the error occur again?
    Connect the cable properly. Turn off and on the MFP. Replace the belt thermistor.
  • Code: 901 ... 904
  • Description: Belt temperature error
    901: Short circuit
    902: Open circuit
    903: High temperature
    904: Low temperature
  • Remedy: Is the cable from the belt thermistor to the CU/PU board connected properly? Does the error occur again?
    Connect the cable properly. Turn off and on the MFP. Replace the belt thermistor.