Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
OKI ES8431
Error Codes List page 3
|
|
- Code: 049
- Display: Service call 049: Error
- Description: Incompatibility between the CU and the engine head type (resolution)
- Remedy: 1) Replace the CU/ PU board with the one for the proper head. 2) Replace with a head of proper resolution.
- Code: 052
- Display: Power off/on 052: Error
- Description: A DMA Abort error was detected with the Image Processor.
- Remedy: Does this error message reappear? Yes Cycle the power. Replace the CU/ PU board.
- Code: 067
- Display: Service call 067: Error
- Description: A communication error was detected during communication with the Sleep Mode interface supervisor program.
- Remedy: Does this error recur? Yes Cycle the power. Replace the CU/ PU board.
- Code: 068
- Display: Service call 068: Error
- Description: The Sleep Mode interface supervisor program was not found.
- Remedy: Does this error recur after power restoration? Yes Program writing by service personnel.
- Code: 069
- Display: Service call 069: Error
- Description: Malfunction of the NIC chip was detected.
- Remedy: Does this error recur? Yes Cycle the power. Replace the CU/ PU board.
- Code: 070
- Display: Power off/on 070: Error
- Description: A PSE firmware error was detected.
- Remedy: Does this error recur? Yes Cycle the power. Replace the CU/ PU board.