Catalog
-
Sign In
-
Contacts
-
Forum
-
Eng
OKI ES3640
Error Codes List page 2
|
|
- Code: 032
- Display: Service Call 032: Error
- Description: CU Slot2 DIMM RAM Check Error
- Causes: Is the applicable RAM DIMM mounted properly? Is operation restored by replacing the applicable RAM DIMM?
- Remedy: Re-mount applicable RAM DIMM. Replace RAM DIMM. Replace CU PCB. (Must replace EEPROM)
- Code: 036
- Display: Service Call 036: Error
- Description: Slot1 RAM Spec error Specification of DIMM in CU RAM slot is unsupported.
- Causes: Is this a standard RAM DIMM? Is the applicable RAM DIMM difference mounted normal? Is operation restored by replacing the applicable RAM DIMM?
- Remedy: Use a standard RAM DIMM. Re-mount applicable RAM DIMM. Replace RAM DIMM Replace CU PCB. (Must replace EEPROM)
- Code: 037
- Display: Service Call 037: Error
- Description: Slot2 RAM Spec error Specification of DIMM in CU RAM slot2 is unsupported
- Causes: Is this a standard RAM DIMM? Is the applicable RAM DIMM difference mounted normal? Is operation restored by replacing the applicable RAM DIMM?
- Remedy: Use a standard RAM DIMM. Re-mount applicable RAM DIMM. Replace RAM DIMM. Replace CU PCB. (Must replace EEPROM)
- Code: 040
- Display: Service Call 040: Error
- Description: CU EEPROM ERROR
- Causes: Is the problem corrected by replacing the CU PCB EEPROM?
- Remedy: REPLACE EEPROM. (User must correct environmental conditions) Replace CU PCB. (Must replace EEPROM)
- Code: 041
- Display: Service Call 041: Error
- Description: CU FLASH ERROR CU PCB flash ROM error
- Causes: Is the error display reproducible?
- Remedy: Replace CU PCB. (Must replace EEPROM)
- Code: 042..045
- Display: Service Call 042: Error to 045: Error
- Description: CU PCB flash ROM error Flash File System Error
- Causes: Failed to access flash memory that is surface-mounted on CU PCB.
- Remedy: Replace CU PCB (Must replace EEPROM)