Remedy: 1. There are not the movement restrictions, but early replace the Print Head.
Code: 10e
Display: SYSTEM HALT (*) 10e :FROM CLEAR
Description: F-ROM CLEAR error (F-ROM clear unable) F-ROM is not clearable on Parameter writing, FW down loading and Log clearing. (fls_secclr)
Remedy: 1. Execute the memory check (F-ROM) of [#TEST]. 2. Upload the parameter and initialize all parameters with [#PARAMETER]. 3. Replace the MAIN PCB with a new one.
Code: 10f
Display: SYSTEM HALT (*) 10f : FROM WRITE
Description: FROM WRITE error (F-ROM writing unable) F-ROM is not clearable on Parameter writing, FW down loading and Log clearing. (fls_secclr)
Remedy: 1. Execute the memory check (F-ROM) of [#TEST]. 2. Upload the parameter and initialize all parameters with [#PARAMETER]. 3. Replace the MAIN PCB with a new one.
Code: 110
Display: SYSTEM HALT (*) 110 : PCB KEY
Description: No Keyboard PCB
Remedy: 1. Check the connections between the Keyboard PCB and the MAIN PCB and then disconnect and connect the FFCs. 2. Replace the FFCs of the above routes. 3. Replace the Keyboard PCB with a new one. 4. Replace the MAIN PCB with a new one.
Code: 120
Display: SYSTEM HALT (*) 120 : LCD THERM.
Description: LCD thermistor IC RW error
Remedy: 1. Check the connections between the Keyboard PCB and the MAIN PCB, and then disconnect and connect the FFCs. 2. Replace the FFCs and the cabeles of the above routes. 3. Replace the Keyboard PCB with a new one. 4. Replace the MAIN PCB with a new one. 5. Replace the DC Power Supply(5V) with a new one.
Code: 122
Display: ERROR 122 CHECK:SDRAM
Description: PRAM size is not sufficient at FW upgrading (fw_updmsg).
Remedy: 1. Update F/W. 2. Replace the MAIN PCB with a new one. 3. Replace the PRAM PCB with a new one.