  • Code: 951.xx
  • Description: Error with secure NVRAM on the controller board
  • Remedy: Replace the controller board.
  • Code: 952.xx
  • Description: A recoverable MVRAM Cyclic Redundancy Check error occurred.
  • Remedy: Performing POR will clear this error.
  • Code: 953.xx
  • Description: NVRAM chip failure with mirror
  • Remedy: Replace the operator panel.
  • Code: 954.xx
  • Description: NVRAM chip failure with system part.
  • Remedy: Replace the controller board.
  • Code: 955.xx
  • Description: The code ROM or NAND flash failed the Cyclic Redundancy Check or the NAND experienced an uncorrectible multi-bit failure.
  • Remedy: Replace the controller board.
  • Code: 956.00
  • Description: RIP card failure: processor failure
  • Remedy: Replace the controller board.