Description: Billing counting error A checksum error is detected in the main and engine backup memories for the billing counters.
Causes: Data damage of EEPROM. Defective PWB. EEPROM.
Remedy: Data damage of EEPROM. Contact the Service Administrative Division. Defective PWB. Replace the main PWB or the engine PWB and check for correct operation.
Remedy: Replace the engine PWB and check for correct operation.
Code: 0800
Description: Image processing error JAM010x is detected twice.
Causes: Defective main PWB.B.
Remedy: Replace the main PWB and check for correct operations page 1-5-22).
Code: 0840
Description: Faults of RTC The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
Causes: The battery is disconnected from the main PWB. Defective main PWB.
Remedy: The battery is disconnected from the main PWB. Check visually and remedy if necessary Defective main PWB. Replace the main PWB and check for correct operation.
Code: 1010
Description: Lift motor error (60/50/45 ppm model only) After cassette 1 is inserted, lift sensor does not turn on within 10 s. This error is detected four times successively.
Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB.
Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and engine PWB (YC13) Defective drive transmission system of the lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective lift motor. Replace the lift motor. Defective engine PWB. Replace the engine PWB and check for correct operation.
Code: 1020
Description: PF lift motor 1 error (paper feeder) After cassette 2 is inserted, PF lift sensor 1 does not turn on. This error is detected four times successively.
Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 1 and PF main PWB (YC7) Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective PF lift motor. Replace the PF lift motor 1. Defective PF main PWB. Replace the PF main PWB.