PrintCopy.info service

Konica-Minolta bizhub 5000i

Error Codes List page 2

  • Code: 0405
  • Description: Cannot detect the synchronized signal of the polygon motor for the laser unit (first time).
  • Remedy: 1 Connection failure of the laser unit flat cable.
    Reconnect the laser unit flat cable.
    2 Laser unit flat cable failure.
    Replace the laser unit flat cable.
    3 Laser unit failure.
    Replace the laser unit.
    4 Main PCB failure.
    Replace the main PCB ASSY.
  • Code: 0501
  • Description: The center thermistor of the fuser unit has not reached the specified temperature within the specified time.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit.
    Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the fuser unit heater harness.
    Reconnect the fuser unit heater harness.
    3 Connection failure of the eject sensor harness.
    Reconnect the eject sensor harness.
    4 Connection failure of the lowvoltage power supply harness.
    Reconnect the low-voltage power supply harness.
    5 Eject sensor PCB failure.
    Replace the eject sensor PCB ASSY. 6 Fuser unit failure.
    Replace the fuser unit.
    7 Low-voltage power supply PCB failure.
    Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure.
    Replace the main PCB ASSY.
  • Code: 0502
  • Description: The center thermistor of the fuser unit has not reached the specified temperature within the specified time after it was heated normally to the certain level.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit.
    Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the fuser unit heater harness.
    Reconnect the fuser unit heater harness.
    3 Connection failure of the eject sensor harness.
    Reconnect the eject sensor harness.
    4 Connection failure of the lowvoltage power supply harness.
    Reconnect the low-voltage power supply harness.
    5 Eject sensor PCB failure.
    Replace the eject sensor PCB ASSY. 6 Fuser unit failure.
    Replace the fuser unit.
    7 Low-voltage power supply PCB failure.
    Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure.
    Replace the main PCB ASSY.
  • Code: 0503
  • Description: The center thermistor of the fuser unit detected a temperature higher than the specified value.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit.
    Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the fuser unit heater harness.
    Reconnect the fuser unit heater harness.
    3 Connection failure of the eject sensor harness.
    Reconnect the eject sensor harness.
    4 Connection failure of the lowvoltage power supply harness.
    Reconnect the low-voltage power supply harness.
    5 Eject sensor PCB failure.
    Replace the eject sensor PCB ASSY. 6 Fuser unit failure.
    Replace the fuser unit.
    7 Low-voltage power supply PCB failure.
    Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure.
    Replace the main PCB ASSY.
  • Code: 0504
  • Description: After the heat unit was heated normally, the center thermistor of the fuser unit detected a temperature lower than the specified value.
  • Remedy: <User Check>
    • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit.
    Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the fuser unit heater harness.
    Reconnect the fuser unit heater harness.
    3 Connection failure of the eject sensor harness.
    Reconnect the eject sensor harness.
    4 Connection failure of the lowvoltage power supply harness.
    Reconnect the low-voltage power supply harness.
    5 Eject sensor PCB failure.
    Replace the eject sensor PCB ASSY. 6 Fuser unit failure.
    Replace the fuser unit.
    7 Low-voltage power supply PCB failure.
    Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure.
    Replace the main PCB ASSY.
  • Code: 0505
  • Description: The center thermistor of the fuser unit detected a temperature rise greater than the specified value within the specified time.
  • Remedy: <User Check> • Turn OFF the power switch. After several seconds, turn ON the power again and check that this error is reset.
    1 Connection failure of the center or side thermistor harness of the fuser unit.
    Reconnect the center or side thermistor harness of the fuser unit.
    2 Connection failure of the fuser unit heater harness.
    Reconnect the fuser unit heater harness.
    3 Connection failure of the eject sensor harness.
    Reconnect the eject sensor harness.
    4 Connection failure of the lowvoltage power supply harness.
    Reconnect the low-voltage power supply harness.
    5 Eject sensor PCB failure.
    Replace the eject sensor PCB ASSY. 6 Fuser unit failure.
    Replace the fuser unit.
    7 Low-voltage power supply PCB failure.
    Replace the low-voltage power supply PCB ASSY.
    8 Main PCB failure.
    Replace the main PCB ASSY.
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us