PrintCopy.info service

Konica-Minolta bizhub 36

Error Codes List page 3

  • Code: 0510
  • Description: Fusing abnormally low temperature detection (center)
    Detected temperature of the heating roller thermistor (TH2; center) goes below a given temperature for a given period of time consecutively after warm up is completed.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
  • Code: 0511
  • Description: Fusing abnormally low temperature detection (edge)
    Detected temperature of the heating roller thermistor (TH2; edge) goes below a given temperature for a given period of time consecutively after warm up is completed.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
  • Code: 0520
  • Description: Fusing abnormally high temperature detection (center)
    Detected temperature of the heating roller thermistor (TH2; center) goes beyond a given temperature for a given period of time consecutively.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
  • Code: 0521
  • Description: Fusing abnormally high temperature detection (edge)
    Detected temperature of the heating roller thermistor (TH2; edge) goes beyond a given temperature for a given period of time consecutively.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the right door. 3 Check the fusing unit CN30-PRCB CN16, fusing unit-relay CN4AC-DCPU CN2 for proper connection and correct or change as necessary. 4 Change fusing unit 5 Change PRCB 6 Change DCPU
  • Code: 0900
  • Description: Tray 4 lift-up failure (PC-211)
    • The tray 4 upper limit sensor (PS43) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
  • Remedy: 1 Check the connector between M43-PCCB CN4 for proper connection and correct as necessary. 2 Check the connector between M53-PCCB CN8 for proper connection and correct as necessary. 3 Check the connector between PS43-relay CN18-PCCB CN6 for proper connection and correct as necessary. 4 Check the connector between PS53-relay CN18-PCCB CN10 for proper connection and correct as necessary. 5 Check the connector of each motor for proper drive coupling, and correct as necessary. 6 PS43 I/O check, sensor check 7 PS53 I/O check, sensor check 8 M43 operation check 9 M53 operation check 10 Change PCCB 11 Change PRCB
  • Code: 0910
  • Description: Tray 3 feeder up/down abnormality
    The paper feed tray 3 upper limit sensor (PS10) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
  • Remedy: 1 Check the connector between M5-PRCB CN11 for proper connection and correct as necessary. 2 Check the connector of M5 for proper drive coupling and correct as necessary. 3 Check the connector between PS10-relay CN6-PRCB CN14 for proper connection and correct as necessary. 4 PS10 I/O check, sensor check 5 M5 operation check 6 Change M5 7 Change PRCB
Error Code
Service Mode, Troubleshooting
Parts Catalog
Compatibility
Downloads Files
Home
New Register Forgot Password?
Send message to us