PrintCopy.info service

Konica-Minolta bizhub 3320

Error Codes List page 3

  • Code: 111.57
  • Description: Closed-loop printhead error while waiting for amp Ki to converge.
  • Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
    Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
  • Code: 111.58
  • Description: Closed-loop printhead error, load scan regs state.
  • Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
    Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
  • Code: 111.59
  • Description: Closed-loop printhead error, forward and reverse capture times differ by too much.
  • Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
    Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
  • Code: 111.60
  • Description: Closed-loop printhead sweep error, check sweep accuracy state.
  • Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
    Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
  • Code: 111.61
  • Description: Printhead drive control out of range due to an external event beyond what the control is designed to handle.
  • Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.
    Step 2: Inspect the printhead cables and connectors. Are they free of damage? Yes: Replace the controller board. No: Replace the printhead.
  • Code: 111.62
  • Description: Closed-loop printhead error, off-resonant PI effort state.
  • Remedy: Step 1: Check the printhead unit cables JLSU1 and J6 for proper connection. Are they properly connected? Yes: Go to step 2. No: Reseat the cables.