PrintCopy.info service

Konica-Minolta bizhub 130f

Error Codes List page 6

  • Code: T.3.1
  • Description: The page counter in the fax machine detected a document feeder error during transmission. Carefully re-insert the document into the feeder and re-try the call.
  • Remedy:
  • Code: T.4.1
  • Description: No response to MPS/EOP/EOM. Poor phone lines caused the receiving unit to disconnect. Adjust the interval between CFR and data on Memory Switch 11. Try increasing the output levels on Memory Switch 11. It may also be necessary to adjust the transmit speed on Memory Switch 10.
  • Remedy:
  • Code: T.4.2
  • Description: RTN was received from the remote machine. After transmission began, poor line conditions developed. Try the call again. Attempt the solutions described for the T.4.1 error.
  • Remedy:
  • Code: T.4.4
  • Description: Poor line conditions prevented transmission. PIP was received. The transmission was interrupted by the call mode. The receiving unit may be experiencing problems. Try the call again.
  • Remedy:
  • Code: T.5.1
  • Description: No response to RR from the remote machine. Line noise or other problems prevented ECM transmission. Increase the ECM response time on Memory Switch 12.
  • Remedy:
  • Code: T.5.2
  • Description: No response to CTC. Line noise or other problems prevented ECM transmission. Increase the ECM response time on Memory Switch 12.
  • Remedy: