  • Code: 004C
  • Display: OZONE FAN
  • Description: Ozone ventilation fan motor malfunction
    • The ozone ventilation fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the ozone ventilation fan motor is being rotated.
  • Remedy: 1 Check the FM3 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check MFPB PJ31MFPB-3 (LOCK) C-11. 4 Change FM3. 5 Change MFPB.
  • Code: 004E
  • Display: POWER FAN
  • Description: DC power supply fan motor malfunction
    • The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated.
  • Remedy: 1 Check the FM1 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM1 operation check MFPB PJ9MFPB-3 (LOCK) C-10 to 11. 4 Change FM1. 5 Change MFPB.
  • Code: 0060
  • Display: FUSER MOTOR
  • Description: Fusing motor malfunction
    • The fusing motor does not rotate evenly even after the lapse of a given period of time while it is being started. • The motor lock signal remains HIGH for a given period of consecutive time while the fusing motor is being rotated.
  • Remedy: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fuser unit driving mechanism for possible overload and correct as necessary. 3 Check the MFPB connector for proper connection and correct as necessary. 4 M4 operation check MFPB PJ19MFPB-3 to 9 J-3. 5 Change M4. 6 Change MFPB.
  • Code: 0094
  • Display: XFER DETACH 2
  • Description: 2nd image transfer pressure / retraction failure
    • The 2nd image transfer retraction position sensor is not activated (retracted position) within a given period of time after the retraction sequence of the 2nd transfer roller has been started. • The 2nd image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the pressure sequence of the 2nd transfer roller has been started.
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL5 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL5 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS10 sensor check MFPB PJ16MFPB-8 (ON) C-4 7 CL5 operation check MFPB PJ10MFPB-5 (ON) C-6 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3 9 Change M3. 10 Change CL5. 11 Change MFPB.
  • Code: 0096
  • Display: XFER DETACH 1
  • Description: 1st image transfer pressure / retraction failure
    • The 1st image transfer retraction position sensor is not activated (retracted position) within a given period of time after the intermediate transport motor has started rotating. • The 1st image transfer retraction position sensor is not deactivated (pressed position) within a given period of time after the intermediate transport motor has started rotating.
  • Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 Check the CL4 connector for proper connection and correct as necessary. 3 Check M3 for proper drive coupling and correct as necessary. 4 Check CL4 for proper drive coupling and correct as necessary. 5 Check the MFPB connector for proper connection and correct as necessary. 6 PS9 sensor check MFPB PJ7MFPB-11 (ON) J-5. 7 CL4 operation check MFPB PJ19MFPB-2 (REM) J-3 to 4. 8 M3 operation check MFPB PJ11MFPB-1 to 7 J-3. 9 Change M3. 10 Change CL4. 11 Change MFPB.
  • Code: 0300
  • Display: POLYGON MOTOR
  • Description: Polygon motor malfunction
    • The polygon motor does not rotate evenly even after the lapse of a given period of time after it has been started. • The motor lock signal remains HIGH for a given period of consecutive time while the polygon motor is being rotated.
  • Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change MFPB.