  • Code: E-0010
  • Description: Main Motor Error
  • Causes: The Main Motor Output Detection Signal (MAINM_LD) continues to be “H” for 3 seconds or longer when the Main Motor is rotating.
  • Remedy: Wires 1 Is the wire between Main Motor and PW11720 PCB connected properly? No Connect it properly.
    DC Power Supply (DCP1) or Fuse 2 Confirm that the machine is turned on, and then check the voltage of the orange line (J220-5). Is it 24V? No Replace the DC Power Supply if there is no problem with the wires. Confirm that the machine is turned off, and then check whether or not each Fuse is broken. Is any Fuse broken? Yes Replace the Fuse.
    Main Motor (M1) 3 Check the operation of Main Motor in the Operation Check Mode of the Service Mode. Device Code : 00 (Main Motor) Does the Main Motor operate correctly? No Replace the Main Motor.
  • Code: E-0020
  • Description: Counter Error
  • Causes: The Counter Connection Detection Signal (COUNT_OPN) continues to be “L” for 1 second or longer after turning on.
  • Remedy: Service Mode 1 Has the setting of Adjustment Mode Item No.753 set to “1”? Yes Set it to “0”.
  • Code: E-0031
  • Description: Image Corona Output Error
  • Causes: The Image Corona Output Detection Signal (IM_LD) continues to be “L” for 1 second or longer when the Image Corona is ON.
  • Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly.
    Image Corona 3 Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Is the Corona Wire broken? Yes Replace the Corona Wire.
    Cleaning Roller 4 Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft.
    Transfer Corona 5 Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Is the Corona Wire broken? Yes Replace the Corona Wire.
    Separation Corona 6 Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Is the Corona Wire broken? Yes Replace the Corona Wire.
    HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-0032
  • Description: Separation Corona Output Error
  • Causes: The Separation Corona Output Detection Signal (AC_LD) continues to be “L” for 1 second or longer when the Separation Corona is ON.
  • Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly.
    Image Corona 3 Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Is the Corona Wire broken? Yes Replace the Corona Wire.
    Cleaning Roller 4 Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft.
    Transfer Corona 5 Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Is the Corona Wire broken? Yes Replace the Corona Wire.
    Separation Corona 6 Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Is the Corona Wire broken? Yes Replace the Corona Wire.
    HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-0033
  • Description: Transfer Corona Output Error
  • Causes: The Transfer Corona Output Detection Signal (TR_LD) continues to be “L” for 1 second or longer when the Transfer Corona is ON.
  • Remedy: Wire 1 Are wires among Image Corona, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly. 2 (For Image Corona / Cleaning Roller only) Is the spring on the left bottom of the Process Unit OK? No Correct it properly.
    Image Corona 3 Is the Image Corona dirty? Yes Clean each Corona Wire, Grid Plate and housing. Is the Corona Wire broken? Yes Replace the Corona Wire.
    Cleaning Roller 4 Does the bias terminal plate touch to Cleaning Roller shaft properly? No Remove and reapply conductive grease to Cleaning Roller shaft. Relocate the bias terminal plates properly. Is grease applied enough? No Remove and reapply conductive grease to Cleaning Roller shaft.
    Transfer Corona 5 Is the Transfer Corona dirty? Yes Clean each Corona Wire and housing. Is the Corona Wire broken? Yes Replace the Corona Wire.
    Separation Corona 6 Is the Separation Corona dirty? Yes Clean each Corona Wire and housing. Is the Corona Wire broken? Yes Replace the Corona Wire.
    HV Power Supply 7 Can you fix the problem if you replace the HV Power Supply? Yes OK
  • Code: E-0034
  • Description: Bias Output Error
  • Causes: Bias Output Detection Signal (BIAS_LD) continues to be “L” for 1 second or longer when a specified bias is supplied to the corresponding Developer Unit components.
  • Remedy: Wires 1 Are wires among Developer Unit, HV Power Supply PCB and PW11720 PCB connected properly? No Connect them properly.
    Developer Unit 2 Is the toner spill out from the Developer Unit? (Or is there any similar problem?) Yes Clean each Corona Wire, Grid Plate and housing. Is the high voltage of Regulation Roller leaking? (The resistance between the central part of Regulation Roller and the Ground is 5 mega ohm or smaller if leaking.) Yes Replace the Regulation Roller.
    HV Power Supply 3 Can you fix the problem if you replace the HV Power Supply? Yes OK