PrintCopy.info service

Canon iRC3220N

Error Codes List page 2

  • Code: E002-0003
  • Description: The rise in temperature of the fixing unit is inadequate.
    The output of the non-contact thermistor does not reach 90°C within 180 sec after it has reached 60°C.
  • Code: E002-0004
  • Description: The rise in temperature of the fixing unit is inadequate.
    The output of the non-contact thermistor does not reach 120°C within 240 sec after it has reached 90°C.
  • Code: E002-0005
  • Description: The rise in temperature of the fixing unit is inadequate.
    The output of the non-contact thermistor does not reach 140°C within 180 sec after it has reached 120°C.
  • Code: E002-0006
  • Description: The rise in temperature of the fixing unit is inadequate.
    The output of the non-contact thermistor does not reach 160°C within 180 sec after it has reached 140°C.
  • Code: E002-0007
  • Description: The rise in temperature of the fixing unit is inadequate.
    The output of the non-contact thermistor does not reach 180°C within 180 sec after it has reached 160°C.
  • Code: E002-0008
  • Description: The rise in temperature of the fixing unit is inadequate.
    The output of the non-contact thermistor does not reach 190°C within 180 sec after it has reached 180°C.