Description: Abnormality of the fixing unit
A break in the non-contact thermistor film The status that A/D of the non-contact thermistor film is FFh continues for 500msec.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Code: E001-0007
Description: Abnormality of the fixing unit
A short circuit in the non-contact thermistor film The status that A/D of the non-contact thermistor film is 30h or less continues for 500msec.
Remedy: Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Code: E001-0008
Description: Abnormality of the fixing unit
A break in the non-contact thermistor case The status that A/D of the non-contact thermistor case is FFh continues for 500msec.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Code: E001-0009
Description: Abnormality of the fixing unit
A short circuit in the non-contact thermistor case The status that film A/D-case A/D of the non-contact thermistor is 0C or more continues for 700msec.
Remedy: Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Code: E001-0010
Description: Abnormality of the fixing unit
A break in the end thermistor The status that A/D of the contact thermistor case is FFh continues for 500msec
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Code: E001-0011
Description: Abnormality of the fixing unit
A short circuit in the end thermistor The status that A/D of the contact thermistor case is 39h or less continues for 500msec.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR