  • Code: E004-0201
  • Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    At power-on (or, when IH is at reset), the IH control mechanism is not in an initial state.
  • Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
  • Code: E004-0202
  • Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    At IH start-up, the IH control enable flag is not set within 1 sec after the start flag is set.
  • Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
  • Code: E004-0203
  • Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    With IH at rest, the IH control flag is not released.
  • Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
  • Code: E004-0204
  • Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    The 12-V power supply (IH relay) is identified as being off.
  • Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
  • Code: E004-0205
  • Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    At IH start-up, the PWM/ON data is faulty ('0' or 'FFFF')
  • Remedy: - Replace the DC controller PCB.
  • Code: E005-0000
  • Description: There is no fixing web/there is an error in the detection of web solenoid connection.
    The absence of the fixing web has been detected for 5 sec or more.
  • Remedy: - Replace the fixing web. - Replace the fixing web length sensor. - Replace the DC controller PCB. After correcting the fault, be sure to reset the fixing web counter reading. (COPIER>COUNTER>MISC>FIX-WEB)