Description: The rotation of the fixing film is faulty.
While the fixing motor is rotating, the marker signal is not detected for 6 sec with the reading of the main thermistor indicating 100 deg C or more.
Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR. Replace the main thermistor. Replace the DC controller PCB.
Code: E010-0001
Description: The rotation of the main motor is faulty.
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
Remedy: Replace the main motor. Replace the DC controller PCB.
Code: E010-0002
Description: The rotation of the main motor is faulty.
During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
Remedy: Replace the main motor. Replace the DC controller PCB.
Code: E014-0001
Description: The rotation of the fixing motor is faulty.
Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec
Remedy: Replace the fixing motor. Replace the DC controller PCB.
Code: E014-0002
Description: The rotation of the fixing motor is faulty.
During motor rotation, detection is executed every 100 msec; however, the drive signal is absent 5 times in sequence.
Remedy: Replace the fixing motor. Replace the DC controller PCB.
Code: E019-0000
Description: The waste toner case is full, or the waste toner case full sensor is faulty
When the waste toner case is identified as being full for 2000 prints continuously, an alert is issued; thereafter, the case is identified as being full continuously for 100 prints
Remedy: Replace the waste toner sensor. Replace the DC controller PCB.