  • Code: E001-0010
  • Description: The over-rising in temperature of the fixing assembly is detected.
    The power is turned off and then on without clearing the error.
  • Remedy: - Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E002-0000
  • Description: The rise in temperature of the fixing assembly is faulty.
    The reading of the main thermistor (TH1) does not reach 100 deg C 2 min 30 sec after it has exceeded 70 deg C.
  • Remedy: - Check if the connector (J505) of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly. - Check the wiring between the thermistor and the DC controller. -Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the fixing heater. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E002-0001
  • Description: The rise in temperature of the fixing assembly is faulty.
    The reading of the main thermistor does not reach 150 deg C within 2 min 30 sec after it has exceeded 100 deg C.
  • Remedy: - Check if the connector (J505) of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly. - Check the wiring between the thermistor and the DC controller. -Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the fixing heater. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E002-0010
  • Description: The rise in temperature of the fixing assembly is faulty.
    The power has been turned off and then on without clearing the error.
  • Remedy: - Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E003-0000
  • Description: The fixing temperature is too low after a standby state.
    The reading of the main thermistor is 70 deg C or lower for 2 sec or more after it has reached 100 deg C.
  • Remedy: - Check if the connector (J505) of the DC controller PCB is mounted properly and also check if the connector of the fixing assembly is mounted properly. - Check the wiring between the thermistor and the DC controller. -Check if the main thermistor is mounted properly and also check if there is no contamination. - Replace the main thermistor. - Replace the fixing heater. - Replace the AC driver PCB. - Replace the DC controller PCB. Caution You must clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).
  • Code: E003-0010
  • Description: The fixing temperature is too low after a standby state.
    The power has been turned off and then on without clearing the error.
  • Remedy: - Clear the error in service mode (COPIER>FUNCTION>CLEAR>ERR).