  • Code: E001-0013
  • Description: Fixing sub thermistor 2 (THM4) abnormal temperature rise. Fixing sub thermistor 2 (THM4) detected abnormal high temperature. (software detection)
  • Remedy: Check the detection temperature of the fixing sub thermistor 2 (THM4) in service mode (COPIER> DISPLAY> ANALOG> FIX-UE2). A. In case that the detection temperature is 250 degC A-1. The cable of the fixing sub thermistor 2 is caught -> replace the fixing film unit B. In case that the detection temperature is other than 250 degC B-1. Location of the fixing main thermistor is inappropriate -> replace the fixing film unit B-2. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR
  • Code: E001-0014
  • Description: Abnormal temperature rise of Fixing Edge Rear Thermistor (THM5). The Fixing Edge Rear Thermistor (THM5) detected abnormal high temperature (software detection).
  • Remedy: Check the detected temperature of the Fixing Edge Rear Thermistor (THM5) in service mode (COPIER > DISPLAY > ANALOG > FIX-UE). A. When the detected temperature was 260 deg C or higher A-1. Cable of the Fixing Edge Rear Thermistor is caught. -> Replace the Fixing Film Unit. B. When the detected temperature was lower than 260 deg C B-1. The Fixing Main Thermistor is not securely attached. -> Replace the Fixing Film Unit. B-2. Replace the DC Controller PCB. NOTE: After performing the remedy work above, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR.
  • Code: E001-0015
  • Description: Abnormal Temperature Rise of Fixing Edge Front Thermistor (THM2). The Fixing Edge Front Thermistor (THM2) detected abnormal high temperature (software detection)
  • Remedy: Check the detected temperature of the Fixing Edge Front Thermistor (THM2) in service mode (COPIER > DISPLAY > ANALOG > FIX-UE2) A. When the detected temperature was 260 deg C or higher A-1. Cable of the Fixing Edge Front Thermistor is caught. -> Replace the Fixing Film Unit. B. When the detected temperature was lower than 260 deg C B-1. The Fixing Main Thermistor is not securely attached. -> Replace the Fixing Film Unit. B-2. Replace the DC Controller PCB. NOTE: After performing the remedy work above, go through the following to clear the error: COPIER > FUNCTION > CLEAR > ERR
  • Code: E003-0001
  • Description: Fixing Film abnormally low temperature. After standby, fixing main thermistor (THM1) detected less or equal to 110 degrees Celsius in succession for 1 second.
  • Remedy: 1. Check the rear louver. (If the rear of the machine is close to the wall, temperature of the power supply area may rise) 2. Check the detection temperature of the thermistor in service mode (COPIER> DISPLAY> ANALOG> FIXxx). A. In case that either one of the thermistor detection temperature is risen A-1. Check the fixing film unit (to see if the location of the thermistor is inappropriate or the thermistor failure) -> replace the fixing film unit A-2. Faulty drawer connector -> clean the drawer connector or replace the fixing drawer cable B. In case that neither of them are not risen B-1. Check the connection of the fixing thermistor (to see if the connection of the drawer is faulty, the connector is physically removed or disconnected) -> replace the fixing film unit B-2. Check the connection of the IH power connector (to see if the connector is physically removed or disconnected, or the cable is caught) B-3. Replace the IH power unit B-4. Replace the DC controller PCB NOTE: After performing the above remedy work, go through the following to clear the error: COPIER> FUNCTION> CLEAR> ERR
  • Code: E004-0201
  • Description: Fixing Film temperature difference error 1. Difference of detected temperature between the fixing subthermistor 2 (THM4) and the fixing subthermistor 1 (THM3) is bigger than the rated value.
  • Remedy: 1. Fixing main /sub thermistor (THM1-1/2/3) connector disconnetion (pinching wire, broken wire) -> replace the fixing film unit 2. Check the rotation of the fixing motor (to see if the connector is physically removed or disconnected) -> replace the fixing motor or the harness 3. Faulty drawer connector -> clean the drawer connector or replace the fixing drawer cable 4. Replace the DC controller PCB
  • Code: E004-0202
  • Description: Fixing Film temperature difference error 2. Difference of detected temperature between the fixing main thermistor (THM1) and the fixing subthermistor 1 (THM3) are bigger than the rated value.
  • Remedy: 1. Fixing main /sub thermistor (THM1-1/2/3) connector disconnetion (pinching wire, broken wire) -> replace the fixing film unit 2. Check the rotation of the fixing motor (to see if the connector is physically removed or disconnected) -> replace the fixing motor or the harness 3. Faulty drawer connector -> clean the drawer connector or replace the fixing drawer cable 4. Replace the DC controller PCB