PrintCopy.info service

Canon iR Advance C256i

Error Codes List page 3

  • Code: E003-A003-05
  • Description: Sub Thermistor (Rear) low temperature detection error
  • Causes: The Sub Thermistor (Rear) detected a temperature of 80 deg C or lower for 1 sec or longer from start of PI control until completion of the last rotation (the Fixing Heater is turned OFF) during printing.
  • Remedy: [Related parts] R1.00 - Harness between the Fixing Drawer (DR01/J5401) and the Low-voltage Power Supply PCB (UN01/J302) - Harness between the Low-voltage Power Supply PCB (UN01/J315 and J322) and the DC Controller PCB (UN04/J20 and J22) - Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) - Fixing Assembly - Low-voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E004-0001-05
  • Description: Fixing Relay welding detection error
  • Causes: Zero cross interruption was detected although the Fixing Relay was not turned ON.
  • Remedy: [Remedy] Check/replace the Low-voltage Power Supply PCB. (UN01) [Caution] Since an electrical trouble due to error in fixing safety circuit relay is the cause of the error, be sure to replace the Low-voltage Power Supply PCB.
  • Code: E004-0002-05
  • Description: Main Thermistor and Sub Thermistor (Rear) disconnection detection error
  • Causes: Connection could not be detected within 0.5 sec when power was supplied to the Fixing Heater.
  • Remedy: [Related parts] R1.00 - Harness between the Fixing Drawer (DR01/J5401) and the DC Controller PCB (UN04/J134) - Fixing Assembly - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E009-0001-05
  • Description: Fixing pressure timeout error
  • Causes: Signal of the Fixing Pressure Release Sensor could not be detected at pressure application operation of the Fixing Pressure Release Cam, and the operation was not completed within 4 sec from the start of counterclockwise rotation of the Fixing Motor.
  • Remedy: [Related parts] R1.01 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Harness between the Low-voltage Power Supply PCB (UN01/J315 and J322) and the DC Controller PCB (UN04/J20 and J22) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - Low Voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. If periodic sound has occurred, check/replace the Fixing Assembly, Low-voltage Power Supply PCB, DC Controller PCB, and related harness. 2. If the Delivery Roller is rotating without noise, or if noise of the gear teeth being improperly meshed has occurred, check/replace the Fixing Drive Unit. 3. If the Delivery Roller is not rotating, check/replace the Fixing Motor, Fixing Drive Unit, Lowvoltage Power Supply PCB, DC Controller PCB, and related harness. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E009-0002-05
  • Description: Fixing disengagement timeout error
  • Causes: Signal of the Fixing Pressure Release Sensor could not be detected at pressure release operation of the Fixing Pressure Release Cam, and the operation was not completed within 4 sec from the start of counterclockwise rotation of the Fixing Motor.
  • Remedy: [Related parts] R1.01 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Harness between the Low-voltage Power Supply PCB (UN01/J315 and J322) and the DC Controller PCB (UN04/J20 and J22) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - Low Voltage Power Supply PCB (UN01) - DC Controller PCB (UN04) [Remedy] Perform the following in the order while checking whether the error is cleared. 1. If periodic sound has occurred, check/replace the Fixing Assembly, Low-voltage Power Supply PCB, DC Controller PCB, and related harness. 2. If the Delivery Roller is rotating without noise, or if noise of the gear teeth being improperly meshed has occurred, check/replace the Fixing Drive Unit. 3. If the Delivery Roller is not rotating, check/replace the Fixing Motor, Fixing Drive Unit, Lowvoltage Power Supply PCB, DC Controller PCB, and related harness. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
  • Code: E009-0003-05
  • Description: Fixing pressure retry error
  • Causes: Signal of the Fixing Pressure Release Sensor could not be detected at pressure application operation of the Fixing Pressure Release Cam, and the operation was not completed within 3 times from the start of counterclockwise rotation of the Fixing Motor.
  • Remedy: [Related parts] R1.00 - Harness between the DC Controller PCB (UN04/J134) and the Fixing Drawer (DR01/J5401) - Harness between the Fixing Drawer (DR01/J5401) and the Fixing Pressure Release Sensor (PS13/J5403) - Harness between the DC Controller PCB (UN04/J135) and the Fixing Motor (M04/J5412) - Fixing Pressure Release Sensor (PS13) - Fixing Motor (M04) - Fixing Drive Unit - Fixing Assembly - DC Controller PCB (UN04) [Remedy] Check/replace the related harness/cable, connector and parts. Be sure to preferentially check the Fixing Drive Unit. [Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2 min) and restore the backup data after the replacement so the data may be able to be protected. - Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP - Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRE