  • Code: E804-0000
  • Description: Power Supply Cooling Fan error
    Lock of the Power Supply Cooling Fan is detected
  • Remedy: 1. Check power supply to the Power Supply Cooling Fan (FM1) 2.Replace the Power Supply Cooling Fan
  • Code: E806-0001
  • Description: Error detection of 3 Way Unit Cooling Fan
    When lock of the 3 Way Unit Cooling Fan was detected out for 15 sec
  • Remedy: The Fan is physically locked or failed, or electrical trouble 1. COPIER > FUNCTION > PART-CHK > FAN; and then move FM04 When the 3 Way Unit Cooling Fan (FM04) works 2-1. Check the harness/connector between the DC Controller PCB (UN09) and the 3 Way Unit Cooling Fan (FM04) 3-1. Replace the 3 Way Unit Cooling Fan (FM04) 4-1. Replace the DC Controller PCB (UN09) When the 3 Way Unit Cooling Fan (FM04) does not work 2-2. Turn the 3 Way Unit Cooling Fan (FM04) with your hand to check for rotation of the fan 3-2. Check the harness/connector between the DC Controller PCB (UN09) and the 3 Way Unit Cooling Fan (FM04) 2. Check conduction of FU11 in the DC Controller PCB (UN09) When the fuse is blown out 5-2-1. Replace the DC Controller PCB (UN09) When the fuse is not blown out 5-2-2. Replace the 3 Way Unit Cooling Fan (FM04) 6-2-2. Replace the DC Controller PCB (UN09)
  • Code: E807-0001
  • Description: Error detection of Drum Unit Cooling Fan
    Lock of the Drum Unit Cooling Fan was detected out for 15 sec
  • Remedy: The Fan is physically locked or failed, or electrical trouble 1.COPIER > FUNCTION > PART-CHK > FAN; and then move FM07 When the Drum Unit Cooling Fan (FM07) works 2-1. Check the harness/connector between the DC Controller PCB (UN09) and the Drum Unit Cooling Fan (FM07) 3-1. Replace the Drum Unit Cooling Fan (FM07) 4-1. Replace the DC Controller PCB (UN09) When the Drum Unit Cooling Fan (FM07) does not work 2-2. Turn the Drum Unit Cooling Fan (FM07) with your hand to check for rotation of the fan 3-2. Check the harness/connector between the DC Controller PCB (UN09) and the Drum Unit Cooling Fan (FM07) 4-2. Check conduction of FU9 in the DC Controller PCB (UN09) When the fuse is blown out 5-2-1. Replace the DC Controller PCB (UN09) When the fuse is not blown out 5-2-2. Replace the Drum Unit Cooling Fan (FM07) 6-2-2. Replace the DC Controller PCB (UN09)
  • Code: E808-0001
  • Description: Zero cross signal detection error
    Unable to detect 43 to 57Hz for 5000 msec or longer at the start of zero cross detection
  • Remedy: Electrical trouble with failed zero cross signal 1. Check failure between the AC Driver PCB (UN14/ J122) and the DC Controller PCB (UN09/ J10). (trapped cable, open circuit, connector disconnection) -> Replace the part in the case of trapped cable/open circuit 2. Replace the AC Driver PCB (UN14) 3. Replace the DC Controller PCB (UN09) 4. Check the power supply condition at the customer site. When it is below 43 to 57Hz, ask for a construction work.
  • Code: E808-0002
  • Description: Zero cross signal detection error
    Unable to detect 43 to 57Hz for 500 msec or longer after confirmation of a zero cross cycle
  • Remedy: Electrical trouble with failed zero cross signal 1. Check failure between the AC Driver PCB (UN14/ J122) and the DC Controller PCB (UN09/ J10). (trapped cable, open circuit, connector disconnection) -> Replace the part in the case of trapped cable/open circuit 2. Replace the AC Driver PCB (UN14) 3. Replace the DC Controller PCB (UN09) 4. Check the power supply condition at the customer site. When it is below 43 to 57Hz, ask for a construction work.
  • Code: E880-0001
  • Description: Controller Fan error
    Lock of Controller Fan is detected
  • Remedy: Check if the connector is connected If the connector is OK, replace Controller Fan (FM3)