Description: Startup error
The temperature detected by the main or sub thermistor does not rise to the specified value during startup control.
Remedy: - Check the fixing film connector. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E001-0000
Description: Abnormally high temperature (detected by main thermistor)
The main thermistor detected an abnormally high temperature 235 deg C) during temperature control
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.
Code: E001-0001
Description: Abnormally high temperature (detected by sub thermistor)
The sub thermistor detected an abnormally high temperature (300 deg C) during temperature control.
Remedy: - Check the connector of the fixing film unit. - Replace the fixing film unit. - Replace the DC controller PCB.