PrintCopy.info service

Canon MF244dw

Error Codes List page 3

  • Code: 0071H
  • Description: Timing Error
  • Remedy:
  • Code: 0094H
  • Description: Initial Stationary
  • Remedy:
  • Code: 0095H
  • Description: Pickup NG
  • Remedy:
  • Code: E000 0000
  • Description: Fixing Assembly does not start up within specified time.
  • Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check that the heater resistance measured between 1PIN and 2PIN of the cable (J101) on the DC Controller Board is in the following range. Replace the Fixing Assembly when the resistance value is abnormal. [1] 120 V machine - Heater resistance: 16.0 Ù ±7% [2] 230 V machines - Heater resistance: 53.8 Ù ±7% 2. Check the connection of connector (J101) on the DC Controller Board. 3. Check the connection of connector (J552) on DC Controller Board. 4. Replace the Fixing Assembly. 5. Replace the DC Controller Board.
  • Code: E001 0000
  • Description: Abnormal high-temperature detection
  • Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check that the heater resistance measured between 1PIN and 2PIN of the cable (J101) on the DC Controller Board is in the following range. Replace the Fixing Assembly when the resistance value is abnormal. [1] 120 V machine - Heater resistance: 16.0 Ù ±7% [2] 230 V machines - Heater resistance: 53.8 Ù ±7% 2. Check the connection of connector (J101) on the DC Controller Board. 3. Check the connection of connector (J552) on DC Controller Board. 4. Replace the Fixing Assembly. 5. Replace the DC Controller Board.
  • Code: E003 0000
  • Description: Abnormal low-temperature detection
  • Remedy: When the same error repeatedly occurs after several times of turning the power OFF/ON, execute the following remedies. 1. Check that the heater resistance measured between 1PIN and 2PIN of the cable (J101) on the DC Controller Board is in the following range. Replace the Fixing Assembly when the resistance value is abnormal. [1] 120 V machine - Heater resistance: 16.0 Ù ±7% [2] 230 V machines - Heater resistance: 53.8 Ù ±7% 2. Check the connection of connector (J101) on the DC Controller Board. 3. Check the connection of connector (J552) on DC Controller Board. 4. Replace the Fixing Assembly. 5. Replace the DC Controller Board.