PrintCopy.info service

Canon LBP7780Cx

Error Codes List page 3

  • Code: E012-0006
  • Description: ITB motor or drum motor failure
  • Causes: Cyan drum motor error (Failure in drum motor initial operation) The target speed was not reached within a specified time after startup of the motor.
  • Remedy: • Check the contact of the connector between the drum motor (J515) and the DC controller PCB (J81). • Replace the drum motor. • Replace the main drive assembly.
  • Code: E012-0007
  • Description: ITB motor or drum motor failure
  • Causes: Cyan drum motor error (Failure in drum motor rotation) The motor rotated out of the target speed during rotation after the target speed was reached.
  • Remedy: • Check the contact of the connector between the drum motor (J515) and the DC controller PCB (J81). • Replace the drum motor. • Replace the main drive assembly.
  • Code: E012-0008
  • Description: ITB motor or drum motor failure
  • Causes: Black drum motor error (Failure in drum motor initial operation) The target speed was not reached within a specified time after startup of the motor.
  • Remedy: • Check the contact of the connector between the drum motor (J515) and the DC controller PCB (J81). • Replace the drum motor. • Replace the main drive assembly.
  • Code: E012-0009
  • Description: ITB motor or drum motor failure
  • Causes: Black drum motor error (Failure in drum motor rotation) The motor rotated out of the target speed during rotation after the target speed was reached.
  • Remedy: • Check the contact of the connector between the drum motor (J515) and the DC controller PCB (J81). • Replace the drum motor. • Replace the main drive assembly.
  • Code: E013-0000
  • Description: Residual toner feed motor failure
  • Causes: Residual toner feed motor failure
  • Remedy: • Check the contact of the connector between the Residual toner feed motor (J89L) and the DC controller PCB (J137). • Replace the Residual toner feed motor
  • Code: E014-0000
  • Description: Fixing motor failure
  • Causes: Fixing motor startup error The target speed was not reached within a specified time after startup of the motor
  • Remedy: • Check the contact of the connector between the fixing motor (J516) and the DC controller PCB (J81). • Check the gear between the fixing motor and the fixing assembly. • Replace the fixing motor.