  • Code: E808-0001
  • Description: Low-voltage power supply failure
  • Causes:
  • Remedy:
  • Code: E825-0000
  • Description: Drum phase control sensor failure warning
  • Causes: Yellow drum phase control sensor failure warning A slit was not detected for 4 seconds after slit detection started. An abnormal slit width was detected.
  • Remedy: Check the YMC drum drive gear. Replace the YMC drum HP sensor (PS13).
  • Code: E825-0001
  • Description: Drum phase control sensor failure warning
  • Causes: Magenta drum phase control sensor failure warning A slit was not detected for 4 seconds after slit detection started. An abnormal slit width was detected.
  • Remedy: Check the YMC drum drive gear. Replace the YMC drum HP sensor (PS13).
  • Code: E825-0002
  • Description: Drum phase control sensor failure warning
  • Causes: Cyan drum phase control sensor failure warning A slit was not detected for 4 seconds after slit detection started. An abnormal slit width was detected
  • Remedy: Check the YMC drum drive gear. Replace the YMC drum HP sensor (PS13).
  • Code: E825-0003
  • Description: Drum phase control sensor failure warning
  • Causes: Black drum phase control sensor failure warning A slit was not detected for 4 seconds after slit detection started. An abnormal slit width was detected.
  • Remedy: Check the Bk drum drive gear. Replace the Bk drum HP sensor (PS12).
  • Code: E825-0004
  • Description: Drum phase control sensor failure warning
  • Causes: OHT sensor failure warning
  • Remedy: