PrintCopy.info service

Brother MFC9420CN

Error Codes List page 3

  • Code: 2C
  • Description: Fuser temperature low error at warming-up.
  • Causes: Contact Failure of Harness Connector Low Input Voltage
  • Remedy: Contact Failure of Harness Connector Confirm the connection of Harness Connector Low Input Voltage Connect the printer with the rated voltage source.
  • Code: 2D
  • Description: Fuser temperature low error
  • Causes: Low Input Voltage
  • Remedy: Low Input Voltage Connect the printer with the rated voltage source.
  • Code: 2E
  • Description: Fuser temperature high error
  • Causes: Breakdown of Heater On/Off Circuit Breakdown of Temp Control Circuit
  • Remedy: Breakdown of Heater On/Off Circuit Replace the LV Power Supply PCB Breakdown of Temp Control Circuit Replace the engine controller board
  • Code: 2F
  • Description: Fuser ACOFF error.
  • Causes: Breakdown of Heater On/Off Circuit Breakdown of Temp Control Circuit
  • Remedy: Breakdown of Heater On/Off Circuit Replace the LV Power Supply PCB Breakdown of Temp Control Circuit Replace the engine controller board
  • Code: 30
  • Description: Erase LED error
  • Causes: Erase lamp defective Engine controller board defective
  • Remedy: Erase lamp defective Replace the erase lamp Engine controller board defective Replace the engine controller board.
  • Code: 31
  • Description: Power supply fan error
  • Causes: Power supply fan defective Engine controller board defective
  • Remedy: Power supply fan defective Replace the power supply fan Engine controller board defective Replace the engine controller board.