Error Codes List page 3
|
|
- Code: 6C
- Description: Heater temperature exceeds the maximum high temperature. (270°C or more is detected for 1 sec.)
- Causes: • Thermistor ASSY • Power supply PCB
- Code: 6D
- Description: Heater temperature lowers the minimum low temperature. (60°C or less is detected for 1 sec.)
- Causes: • Thermistor ASSY • Power supply PCB
- Code: 6E
- Description: Heater temperature does not go up enough. (Slower temperature rise rate than 2°C/5 sec. is detected.)
- Causes: • Halogen lamp • Power supply PCB
- Code: 6F
- Description: Heater hard limiter operates.
- Causes: • Thermistor ASSY • Power supply PCB
- Code: 71
- Description: Scanner motor does not synchronize with the reference clock.
- Causes: • Scanner motor
- Code: 72
- Description: Cannot detect Beam Detect signal.
- Causes: • Scanner motor • MP tray open sensor