  • Code: C1-00
  • Description: MC trouble
    Main charger output abnormality (Output open) Trouble signal is outputted from the high voltage transformer.
  • Causes: The main charger is not installed properly. The main charger is not assembled properly. Disconnection of connector of high voltage transformer. High voltage harness disconnection or breakage.
  • Remedy: Use the SIM 8-2 to check the main charger output. Check for disconnection of the main charger. Replace the high voltage unit.
  • Code: E6-11
  • Description: CSI shading trouble (White correction)
    The CIS white reference plate scan level is abnormal when the lamp is on.
  • Causes: Abnormal harness installation to CIS unit Dirt on the white reference plate. CIS lighting error CIS unit installation trouble CIS unit abnormality Scanner PWB abnormality
  • Remedy: Clean the white reference plate. Check CIS light quantity (SIM 5-3) and lighting. Check CIS unit harness. Check scanner PWB.
  • Code: E6-14
  • Description: CIS communication trouble
    Communication trouble (clock sync) between scanner PWB and CIS-ASIC
  • Causes: Abnormal harness installation to CIS unit CIS unit abnormality Scanner PWB abnormality
  • Remedy: Check CIS unit harness. Check CIS unit. Check scanner PWB.
  • Code: E7-01
  • Description: System data trouble
    When in data storage/acquiring of the HDD system area, the HDD responds an error and does not respond for 30sec, it is judged as a trouble.
  • Causes: The HDD is not properly installed to the ICU PWB. The HDD does not work for the ICU PWB. ICU PWB abnormality
  • Remedy: Check installation of the HDD to the ICU PWB. Check harness connection of the HDD from the ICU PWB. Use SIM62-2, 3 to check the HDD read/write. Replace the HDD. Replace the ICU PWB.
  • Code: E7-02
  • Description: Laser trouble
    BD signal from LSU is kept OFF, or ON.
  • Causes: The connector of LSU or the harness in LSU is disconnected or broken. The polygon motor does not rotate normally. The laser home position sensor in LSU is shifted. The proper voltage is not supplied to the power line for laser. Laser emitting diode trouble PCU PWB trouble ICU PWB trouble
  • Remedy: Check for disconnection of the LSU connector. Use SIM 61-1 to check LSU operation. Check that the polygon motor rotates normally or not. Check light emission of laser emitting diode. Replace the LSU unit. Replace the PCU PWB. Replace the ICU PWB.
  • Code: E7-03
  • Description: HDD trouble
    HDD connection failure If the HDD responds an error or does not respond for 30sec, it is judged as an error. (Other than the system area) Data abnormality in the file management area (when the cluster chain is broken)
  • Causes: HDD is not installed properly to the ICU PWB. HDD does not operate properly in the ICU PWB. ICU PWB trouble
  • Remedy: Check installation of HDD to the ICU PWB. Check connection of the harness of HDD to the ICU PWB. Use SIM 62-2, -3 to check read/write of HDD. Replace HDD. Replace ICU PWB.