Description: Sub CPU Communication Error Disorder of communication with Sub CPU
Causes: Sub Board does not work correctly. Sub CPU does not work correctly. There is a bad connection between Main Board and Sub Board.
Remedy: 1) Check Cable Connection between Main Board and Servo Board 2) Servo Board Replacement 3) Main Board Replacement
Code: 0101
Description: Limit Position Error Limit Initialization in the Service Mode has not been done.
Causes: Limit Initialization in Service Mode has not been done.
Remedy: 1) Carry out Limit Position Initialize.
Code: 0102
Description: Head Lock Sensor Error Even though the machine carries out the regular movement, the output of the Head Lock Sensor does not reach the expected value.
Causes: Head Lock Sensor does not work correctly or is broken.
Remedy: 1) Head Lock Sensor Replacement 2) Check the mechanical Backlash or loose with the scanning axes.
Code: 0103
Description: Limit Sensor Error Even though the machine carries out the regular movement, the output of the Limit Sensor does not reach the expected value
Causes: Limit Sensor does not work correctly or is broken.
Remedy: 1) Limit Sensor Replacement 2) Check the mechanical Backlash or loose with the scanning axes.
Code: 0104
Description: Cap Unit Protection Error Even though the machine carries out the regular movement, the output of Cap Sensor does not reach the expected value.
Causes: Disorder of Cap Motor Fault of Cap Unit Fault of Cap Sensor Cut-line or short-circuit of Cable and Flexible Cable
Remedy: 1) Cap Motor Replacement 2) Cap Unit Replacement 3) Cap Sensor Replacement 4) Cable and Flexible Cable Replacement
Code: 0105
Description: Tool Carriage Connection Error Machine fails to connect the Tool Carriage to the Head Carriage.
Causes: Fault of Tool Carriage Connection Loose of Connection Part Fault of the Limit Position Initialize value Limit Sensor does not work correctly or is broken.
Remedy: 1) Check the mechanical Backlash or loose with the Tool Carriage part. 2) Lock Position Adjustment 3) Limit Position and Cut Down Position Initialize 4) Limit Sensor Replacement