PrintCopy.info service

Konica-Minolta Di3510

Error Codes List page 1

  • Code: C0000
  • Description: Main Motor Failure
    • The Transport Motor Lock signal remains set to H for a set period of time while the Transport Motor is turning.
  • Remedy: 1 Check the M2 connector for proper connection, and correct as necessary 2 Check the M2 for proper drive coupling, and correct as necessary. 3 M2 operation check. 4 Replace PWB-A. 5 Replace PU1.
  • Code: C0010
  • Description: Imaging Unit Motor Failure
    • The Imaging Unit Motor Lock signal remains set to H for a set period of time while the Imaging Unit Motor is turning. • The Imaging Unit Motor Lock signal remains set to L for a set period of time while the Imaging Unit Motor remains stopped.
  • Remedy: 1 Check the M1 connector for proper connection, and correct as necessary. 2 Check the M1 for proper drive coupling, and correct as necessary 3 M1 operation check. 4 Replace PWB-A. 5 Replace PU1.
  • Code: C0044
  • Description: EDH Fan Motor Failure
    • Refer to the Service Manual for the relevant option.
  • Remedy:
  • Code: C0045
  • Description: Cooling Fan Failure
    • The Cooling Fan Motor Lock signal remains set to H for a set period of time while the Cooling Fan Motor is turning. • The Cooling Fan Motor Lock signal remains set to L for a set period of time while the Cooling Fan Motor remains stopped.
  • Remedy: 1 Check the motor connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M5 operation check. 4 Replace PWB-A.
  • Code: C004E
  • Description: Power Unit Cooling Fan Failure
    • The Power Unit Cooling Fan Motor Lock signal remains set to H for a set period of time while the Power Unit Cooling Fan Motor is turning. • The Power Unit Cooling Fan Motor Lock signal remains set to L for a set period of time while the Power Unit Cooling Fan Motor remains stopped.
  • Remedy: 1 Check the motor connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M4 operation check. 4 Replace PWB-A.
  • Code: C004F
  • Description: IU Cooling Fan Failure
    • The I/U Cooling Fan Motor Lock signal remains set to H for a set period of time while the I/U Cooling Fan Motor is turning. • The I/U Cooling Fan Motor Lock signal remains set to L for a set period of time while the I/U Cooling Fan Motor remains stopped.
  • Remedy: 1 Check the motor connectors for proper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M6 operation check. 4 Replace PWB-A.