PrintCopy.info service

Canon iRC3180Ci

Error Codes List page 1

  • Code: E000-0001
  • Description: Insufficient temperature rise of the fixing unit at power-on
    Delay in temperature rise after poweron The non-contact thermistor fails to reach 50 deg C within 180sec after power-on.
  • Remedy: Check on connection of the thermistor/thermo switch, Check on a break in the heater, Replace the cover switch, Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E001-0001
  • Description: Abnormality of the fixing unit
    High temperature of the end thermistor is detected. (Hardware) The hardware detects abnormal high temperature of the end thermistor (230 deg C or higher) for 400msec continuously.
  • Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
  • Code: E001-0002
  • Description: Abnormality of the fixing unit
    High temperature of the non-contact thermistor (Software) Abnormal high temperature (250 deg C or higher) of the non-contact thermistor is detected for 500ms continuously.
  • Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
  • Code: E001-0003
  • Description: Abnormality of the fixing unit
    High temperature of the end thermistor (Software) Abnormal high temperature (220 deg C or more) of the end thermistor is detected for 500ms continuously.
  • Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
  • Code: E001-0004
  • Description: Abnormality of the fixing unit
    Large difference in temperature between end and center Difference in temperature (80 deg C or more) between the non-contact thermistor and the end thermistor is detected for 500msec continuously
  • Remedy: Replace the fixing unit, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION> CLEAR>ERR
  • Code: E001-0005
  • Description: Abnormality of the fixing unit
    Foreign matter in the non-contact thermistor At the end of initial multiple rotations, difference in temperature (20 deg C or more) between the non-contact thermistor and the end thermistor is detected for 200msec continuously.
  • Remedy: Check on remaining paper in the fixing unit, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR