  • Code: E000-0021
  • Description: Within a temperature range of 50°C or lower as detected by the thermistor (TH1), the increase in temperature in 1 min is less than 3°C.
  • Causes: The fixing heater is faulty. The SSR is faulty. The fixing thermistor is faulty. The thermistor (TH1, TH2) has an open circuit. The thermal switch (TP1) has turned on.
  • Code: E000-0031
  • Description: Within a temperature range between 50°C and 190°C as detected by the thermistor, the increase in temperature within 30 sec is less than 5°C.
  • Causes: The fixing heater is faulty. The SSR is faulty. The fixing thermistor is faulty. The thermistor (TH1, TH2) has an open circuit. The thermal switch (TP1) has turned on.
  • Code: E000-0040
  • Description: During standby, the fixing temperature has dropped below 140°C.
  • Causes: The fixing heater is faulty. The SSR is faulty. The fixing thermistor is faulty. The thermistor (TH1, TH2) has an open circuit. The thermal switch (TP1) has turned on.
  • Code: E000-0050
  • Description: During printing, the fixing temperature has dropped below 140°C.
  • Causes: The fixing heater is faulty. The SSR is faulty. The fixing thermistor is faulty. The thermistor (TH1, TH2) has an open circuit. The thermal switch (TP1) has turned on.
  • Code: E000-01
  • Description: Main thermistor (TH1)
  • Causes: The fixing heater is faulty. The SSR is faulty. The fixing thermistor is faulty. The thermistor (TH1, TH2) has an open circuit. The thermal switch (TP1) has turned on.
  • Code: E000-02
  • Description: Sub thermistor (TH2)
  • Causes: The fixing heater is faulty. The SSR is faulty. The fixing thermistor is faulty. The thermistor (TH1, TH2) has an open circuit. The thermal switch (TP1) has turned on.