  • Code: E000-0000
  • Description: Fixing startup failure
  • Causes: The detection temperature of the main thermistor did not increase after start of the power distribution to the heater.
  • Remedy: • Replace the fixing assembly. • Replace the DC controller PCB
  • Code: E001-0000
  • Description: Abnormal high temperature in fixing
  • Causes: The main thermistor detected a temperature of higher than 255 degree C.
  • Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.
  • Code: E001-0001
  • Description: Abnormal high temperature in fixing
  • Causes: The sub thermistor detected a temperature of higher than 290 degree C.
  • Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.
  • Code: E001-0004
  • Description: Abnormal high temperature in fixing
  • Causes: The sub thermistor 2 detected a temperature exceeding a specified temperature.
  • Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.
  • Code: E003-0000
  • Description: Abnormal low temperature in fixing
  • Causes: The main thermistor detected a temperature of lower than 120 degree C for more than 1 second when 20 seconds elapsed after start of the power distribution to the heater.
  • Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.
  • Code: E003-0001
  • Description: Abnormal low temperature in fixing
  • Causes: The sub thermistor detected a temperature of lower than 80 degree C for more than 2 seconds when 20 seconds elapsed after start of the power distribution to the heater.
  • Remedy: • Replace the fixing assembly. • Replace the DC controller PCB.