Ricoh Aficio 350
- Code: SC320
- Description: Polygon motor error
The polygon motor does not reach its operating speed within 20 seconds after the polygon motor on signal, or the lock signal is still activated for more than 20 seconds after the polygon motor off signal. - Causes: • Polygon motor defective • Poor connection between the polygon motor driver and the BICU board • BICU board defective