Konica-Minolta Di151
- Code: C0520
- Description: Abnormally high fusing temperature
The temperature detected by the Thermistor remains higher than 240 °C for a continuous 50 ms period while fusing temperature control is in progress. - Remedy: 1 Thermistor installed at the correct position. NO Correct. 2 Thermistor contaminated. YES Clean. 3 The circuit across CN1-1 and 2 on the Fusing Unit side is shorted as checked with CN1 disconnected. YES Change Thermistor. NO Change Master Board. Change Power Supply Board.
Error Code | |
Service Mode, Troubleshooting | |
Parts Catalog | |
Compatibility | |
Downloads Files | |
Home |