PrintCopy.info service

Sharp MXM950

Error Codes List page 1

  • Code: A0-01
  • Description: PCU ROM abnormality
  • Causes: The firmware is not normally uploaded due to interruption of the power, etc.
  • Remedy: Use Sim. 49-1 to execute firmware upload.
  • Code: A0-02
  • Description: SCU ROM abnormality
  • Causes: The firmware is not normally uploaded due to interruption of the power, etc.
  • Remedy: Use Sim. 49-1 to execute firmware upload.
  • Code: A0-03
  • Description: OPU ROM abnormality
  • Causes: The firmware is not normally uploaded due to interruption of the power, etc.
  • Remedy: Use Sim. 49-1 to execute firmware upload.
  • Code: A0-10
  • Description: Controller ROM error. CTL and the image ROM firmware combination error
  • Causes: CTL and the image ROM firmware combination error.
  • Remedy: Check the firmware combination of CTL and the image ROM.
  • Code: A0-11
  • Description: IF version discrepancy (CTL-PCU). CTL and the PCU firmware combination error
  • Causes: CTL and the PCU firmware combination error
  • Remedy: Check the firmware combination of CTL and the PCU.
  • Code: A0-12
  • Description: IF version discrepancy (CTL-SCU). Firmware combination error between the CTL and the SCU
  • Causes: Firmware combination error between the CTL and the SCU.
  • Remedy: Check the firmware combination of the CTL and the SCU.