Error Codes List page 1
|
|
- Code: A0 30
- Description: Machine configuration error. Discrepancy in the machine composition
- Causes: Discrepancy with the machine configurations. (ANB/AFAX) EEPROM data error
- Remedy: Check to confirm that the machine configurations are compatible with the product specifications. Replace the EEPROM.
- Code: E1 00
- Description: Network board communication trouble. An abnormality occurs in communication between the MCU and the network board.
- Causes: Improper connection of the network board cable Improper firmware Network board abnormality MCU abnormality
- Remedy: Check connection of the network board cable. Update firmware. Replace the MCU and network board with new one.
- Code: E1 01
- Description: Network board command time out error. MCU cannot receive response from the network board while 30sec.
- Causes: Improper connection of the network board cable Improper firmware Network board abnormality MCU abnormality
- Remedy: Check connection of the network board cable. Update firmware. Replace the MCU and network board with new one.
- Code: E1 80
- Description: Network board communication interface error (Break in). A break in error occurs in communication between the CPU and the network board.
- Causes: Improper connection of the network board cable Improper firmware Network board abnormality MCU abnormality
- Remedy: Check connection of the network board cable. Update firmware. Replace the MCU and network board with new one.
- Code: E1 81
- Description: Network board communication interface error (Parity). A parity error occurs in communication between the MCU and the network board.
- Causes: Improper connection of the network board cable Improper firmware Network board abnormality MCU abnormality
- Remedy: Check connection of the network board cable. Update firmware. Replace the MCU and network board with new one.
- Code: E1 82
- Description: Network board communication interface error (Overrun). An overrun error occurs in communication between the MCU and the network board.
- Causes: Improper connection of the network board cable Improper firmware Network board abnormality MCU abnormality