  • Code: L4-05
  • Description: Developing motor trouble (COLOR)
    The motor lock signal is detected during rotation of the developing motor.
  • Causes: Developing motor trouble Developing motor harness and connector connection trouble PCU PWB trouble Developing unit troubl
  • Remedy: Use SIM25-1 to check the operation of the developing motor. Replace the developing motor. Check connection of the developing motor harness and the connection. Replace the PCU PWB. Replace the developing motor. Replace the developing unit.
  • Code: L4-06
  • Description: Transfer unit lift trouble
    A change in the primary transfer position sensor cannot be detected within the specified time in lifting operation of the primary transfer unit.
  • Causes: Transfer unit position sensor trouble Dirt on the transfer unit position sensor. PCU PWB trouble Connection trouble of the connector and the harness. Transfer unit lift mechanism trouble Primary transfer belt unit is not installed.
  • Remedy: Use SIM6-3 to check the separating operation of the transfer unit. Install the primary transfer belt unit. Replace the transfer unit position sensor. Clean the transfer unit position sensor. Replace the PCU PWB. Check connection of the connector and the harness. Repair the transfer unit lift mechanism.
  • Code: L4-07
  • Description: Transfer belt motor trouble
  • Causes: The motor lock signal is detected during rotation of the transfer belt motor. Transfer belt motor trouble Transfer belt motor harness and connector connection trouble PCU PWB trouble
  • Remedy: Use SIM25-1 to check the operation of the transfer belt motor. Check the transfer belt motor, and replace if necessary. Check connection of the harness and connectors of the transfer belt motor, and replace if necessary. Check the PCU PWB, and replace if necessary.
  • Code: L4-11
  • Description: Shift motor trouble
    No change in the shifter home position sensor signal is detected in the operation of the shifter initializing.
  • Causes: Shift motor trouble. PCU PWB trouble. Connection trouble of the connector and the harness. Shifter home position sensor trouble.
  • Remedy: Use SIM6-1 to check the shift operation. Use SIM30-1 to check the operation of the shifter home position sensor. Replace the shift motor. Replace the PCU PWB. Check connection of the connector and the harness. Replace the shifter home position sensor.
  • Code: L4-16
  • Description: Fusing pressure release trouble
    A change in the fusing pressure release sensor signal cannot be detected within the specified time after outputting the fusing pressure release motor.
  • Causes: Fusing pressure release sensor trouble. Fusing pressure release motor trouble. Pressure release drive gear and pressure release idle gear trouble. PCU PWB trouble. Connection trouble of the connector and the harness.
  • Remedy: Replace the fusing pressure release sensor. Replace the fusing pressure release motor. Replace the pressure release drive gear and the pressure release idle gear. Replace the PCU PWB. Check connection of the connector and the harness.
  • Code: L4-30
  • Description: MFP fan motor trouble
  • Causes: Fan motor trouble. MFP PWB trouble.Harness and connector connection trouble. PCU PWB trouble
  • Remedy: Use SIM6-2 to check the operation of the fan motor. Replace the fan motor. Replace the MFP PWB. Check connection of the connector and the harness. Replace the PCU PWB.