  • Description: Polygon motor lock detection
    It is judged that the polygon motor lock signal is not outputted. Lock signal is checked in the interval of 10sec after starting the polygon motor, and it is judged that the polygon motor does not rotate normally.
  • Causes: The LSU connector or harness in the LSU is disconnected or broken. Polygon motor trouble
  • Remedy: Use DIAG (SIM61-1) to check the polygon motor operation. Check connector and harness connection. Replace LSU.